Electrical Safety Analyzer

Test to any standard in minutes with the ESA615
图像
ESA615 front view

Key Features

Automated and portable Electrical Safety Analyzer

ESA615

All-in-one solution with ECG simulator

Easy data entry and storage for test results

Global compliance to electrical safety standards

ESA615 in use

ESA615 Electrical Safety Analyzer: Fast and Versatile

The ESA615 Electrical Safety Analyzer provides automated testing in a portable analyzer. It's a comprehensive solution for healthcare technology professionals who perform electrical safety testing on medical equipment, both in the field and in facilities. As an all-in-one solution, it combines a safety analyzer and ECG simulator in one instrument.

FB ESA615 in hospital setting

User-Friendly Design and Global Compliance

Featuring a portable and ergonomic design, the ESA615 simplifies testing with its user-friendly interface. It offers compliance to key global electrical safety standards such as ANSI/AAMI ES-1 (NFPA-99), IEC62353 (VDE751), IEC60601-1 2nd and 3rd editions, and AS/NZS 3551, making it a versatile tool for global use.

ESA615

Comprehensive Functionality and Ease of Use

With ECG waveform tests and dual-lead measurements, the ESA615 combines the functionality of a simulator and safety analyzer in a single test tool. Data entry is easy via barcode, keyboard, or on-board keypad. The unit also supports custom language selections for English, French, German, Spanish, Italian, and Portuguese.

FBC ESA615 Family

Reliable and Durable for Field Applications

The ESA615 is rigorously tested for rugged field applications, offering replaceable mains fuses to keep your unit operational. It comes with the backing of a global support network, delivering prompt service and peace of mind to Fluke Biomedical customers worldwide. With CE and CSA certifications, it ensures Fluke-quality ruggedness for long-term reliability.

Meet the ESA615 Electrical Safety Analyzer

OneQA Workflow Automation Software

When connected to a PC, running tests is fast and easy with OneQA software. Testing and documenting results is fully automated, saving you valuable time while enhancing accuracy.

Learn more about OneQA

Documentation

Manuals

ESA615 FAQ

ESA615 Getting Started

Available in English(英语), Chinese, French(法语), German(德语), Italian, Japanese, Portuguese

ESA615 Getting Started Supplement

ESA615 Safety Sheet (es)

ESA615 User's Manual

Available in English(英语), Chinese, French(法语), German(德语), Italian, Japanese, Portuguese, Spanish

ESA615 User's Manual Supplement

Datasheet

ESA615 FAQ

White Papers and Application Notes

Intro to Electrical Safety Part I

Models

ESA615 in the box

What comes in the box:

  • Operator’s Manual (multilingual CD) (CD-ROM)
  • Getting Started Guide, hard copy, multilingual (Manual)
  • Ansur Plug-in, CD with demo version (CD-ROM)
  • Data Transfer Cable USA Accessory Kit:
    • Test Lead Set,
    • TP1 Test Probe Set,
  • AC285 Alligator Clip Set (ESA T/L KIT USA)
  • Null Post Adapter (ESA620-NPA)
  • 5-to-5 Banana Jack to ECG (BJ2ECG) Adapter (ESA612-2016)
  • Carrying Case (9530-0075) Power Cord US with C19 Plug (75033)
  • Power Cord NA 220 V (75057) NA 220 V Adapter Kit (1800001)
View all models

Frequently asked questions

Yes, test sequences can be created and modified per user needs.

Many SD cards are compatible, but only the 512MB Industrial Grade SD card that ships with ESA615 has been tested and fully validated. Fluke Biomedical strongly encourages you to use the SD card supplied with the instrument. Additional SD cards are available at a minimal cost.
The ESA615 will attempt to load the last test sequence used on power up. If you have deleted it, for instance by reimaging your card, you will need to select a test sequences from the test library. Push F4 to say "OK" and then push F3 for "Test Library" and either select a test sequence or create a new one to resolve this error.
No. The ESA615 does not have the ability to use a 4-wire method to measure earth conductor integrity. If this method is required, we recommend the ESA620.
Yes, except the limitations mentioned above (MAP source voltage 100 % of mains input and PE test current of 200 mA), the ESA615 tests according to IEC60601 2nd and 3rd editions.
The ESA615 has built-in test sequences for automatic electrical safety testing. These test sequences provide automatic pass/fail indication to NFPA-99 and other international standards. The unit guides you through the test steps quickly and accurately. Customizable test sequences cover ANSI/AAMI ES-1 (NFPA-99), IEC62353 (VDE751), IEC60601-1 (2nd, 3rd edition), or AN/NZS 3551. The ESA615 does not automate other test devices; however, it can be tethered to other test tools using Ansur automation software.
When using the 4-wire method, you are required to null the test lead resistance of your test lead; there is also a slight improvement in test accuracy when the 4-wire method is used. See specifications for detailed comparison.
This is a limitation of the file system on the SD card (FAT16/FAT32). You can avoid this behavior by naming your test with more than 8 characters.