INCU II Incubator/Radiant Warmer Analyzer

Testing incubators and radiant warmers regularly is essential to validate their performance and ensure the safety and comfort of infants.

The Fluke Biomedical INCU II Incubator/Radiant Warmer Analyzer simplifies testing and verifying baby incubators, transport incubators, and radiant warmers are safe and conform to global IEC 60601-2-19 and IEC 60601-2-21 performance standards.

Portable and intuitive-to-use, with a large easy-to-ready LCD screen, the INCU II incubator tester operates as a stand-alone device, simultaneously testing, and storing temperature, airflow, sound, humidity, and other common environmental and operational parameters. Along with standard tests, its on-board automation lets you create customized test groups.

The INCU II incubator analyzer also simplifies test analysis and reporting. Not only are real-time results displayed, but Pass/Fail indicators make it quick to troubleshoot, and pinpoint issues. An Excel add-in allows for detailed test analysis with visual graphs, and the option of creating one-off and standardized reports.

Test results can be saved on the INCU II incubator analyzer or transferred to your computer. The 24 hour battery allows for long-term testing, and the INCU II can store up to 48 hours of test memory.

Pairing the Skin Temperature Heater Assembly (STHA) Accessory with the INCU II, the accuracy of the incubator/radiant warmer’s skin temperature probe can be measured within minutes.

INCU II Incubator/Radiant Warmer Analyzer

  • Enables simultaneous measurement of humidity, airflow, sound, and temperature from six different points
  • Wireless* functionality supports fast and convenient downloading of test results and data
  • Simplifies set-up tests with color-coded temperature probes that match color of input ports
  • Displays pass/fail indicators and real time test results on a large LCD screen
  • Portable and compact design, weighs less than 9 pounds
  • Creates personalized test sequences for automatic test completion
  • Tests accuracy of skin temperature probe with the Skin Temperature Heater Assembly accessory
  • Able to choose from 8 different language interfaces
  • Complies with all global standards, including IEC 60601-2-19, IEC 60601-2-20 and IEC 60601-2-21

*Wireless capabilities not available in all countries. Ask your distributor for more details.

Specifications

Physical Housing
Size (HxWxL w/o sensors)
23 cm x 21 cm x 6 cm (9.0 in x 8.5 in x 2.5 in)
Total weight
3.9 kg (8.5 lb)
Weight with sensors
1.4 kg (3 lb)
Pucks (5)
2.5 kg (5.5 lb)
Carrying case
1.1 kg (2.5 lb)
Power
Power Adapter – Universal voltage
Input: 100 V to 240 V with adaptors 50 Hz/60 Hz
Output: 15V dc, 1.3 A maximum
Rechargeable lithium-ion battery, internal
7.4 V, 7800 mAh, 58 Wh
24 hour battery life with 30 second sample rate
Measurements and tests specifications
Air conduction peripheral temperature sensors for incubator (T1-T5)
5 sensors
Range: 0 °C to 50 °C
Accuracy: ±0.05 °C
Display resolution: 0.01 °C
Air convection temperature sensors for radiant warmers, sensors in pucks (black discs)
5 pucks
Range: 0 °C to 50 °C
Accuracy: ±0.2 °C
Display resolution: 0.01 °C
Relative humidity
Range: 0 % to 100 %,
Accuracy: ±3 % RH (0 % to 100 %, non-condensing)
Display Resolution: 0.1% RH
Airflow
Range: 0.2 m/sec to 2.0 m/sec at 35 C, 50 % RH
Accuracy: ±0.1 m/sec
Display Resolution: 0.01 m/sec
Sound Pressure
30 dB(A) to 100 db(A)
Accuracy: ±5 dB(A)
Display resolution: 0.1 dB(A)
IEC-61672-1 Class 2 from 31.5Hz to 8kHz
Surface temperature
Range: 5 °C to 60 °C
Accuracy: ±0.5 °C
Display Resolution: 0.05 °C
Skin temperature probe with reference thermometer
Range: 0 °C to 50 °C
Accuracy: ±0.05 °C
Display Resolution: 0.01 °C
Environmental specifications
Operating temperature
10 °C to 40 °C
Storage temperature
-20 °C to 60 °C
Humidity
10 % to 90 % non-condensing
Altitude
2000 m
Ingress protection rating
IP-20
Safety
IEC 61010-1
Overvoltage category none, pollution degree 2
IEC 610326-1
Basic
Electromagnetic compatibility (EMC)
Emissions Classification
IEC CISPR11: Group 1, Class A.
Group 1 has intentionally generated and/or use conductively coupled radio-frequency energy, which is necessary for the internal functioning of the equipment itself. Class A equipment is suitable for use in nondomestic locations and/or directly connected to a low voltage power supply network.
USA (FCC)
Intentional radiators
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.(15.19)
Korea (KCC)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
Wireless Module Listing
FCC (United States) compliant (Class A)
FCC ID: X3ZBTMOD3
IC (Industry Canada) compliant
IC: 8828A-MOD3
CE (European) certified
CE0051
802.15.1 qualified
QD ID: B019224
Wireless Radio
Frequency range
2412 to 2483 MHz
Output Power
10 mW
Interface
Push navigation buttons
Power On/Off, Test, Select, Back, and arrow keys
User Preferences
Adjust backlight, display brightness, volume, and set clock
View Verification history
Recall and run templates on tester
General and personalized test templates allow for on-board test automation
Recall past saved and stored tests results
Templates
Time duration, frequency of data capture and tests
Select user preferences
Units of measure, view and print test results of current and past tests on laptop
View battery life
Indicator bar shows life remaining
Interface languages
English, French, German, Italian, Spanish, Brazilian Portuguese, Simplified Chinese, Traditional Chinese, Japanese

*The INCU II software is compatible with Windows 7 and Windows 8. The Excel add-in is compatible with Excel 2010 and 2013.

Model NameDescription
4722635INCU II-NO BT Incubator Analyzer, Non-Wireless
4722620INCU II-BT Incubator Analyzer, Wireless

Batteries, Chargers, and Power Supply
4721194INCU II Adapter - AC Adapter

Cables
4720996INCU II Cable (K-Type Thermocouple)
4721166INCU II USB - Type A to Micro B, USB Cable

Carrying Cases
4724692INCU II Puck case - Soft Carry Case for Pucks
4715749INCU II Carry case - Soft Carry Case

Miscellaneous Accessories
4721017INCU II A F Sensor - Air Flow Sensor
4721153INCU II B Puck - Blue Temperature Puck
4721074INCU II B Sensor - Blue Temperature Sensor
4721127INCU II G Puck - Green Temperature Puck
4721042INCU II G Sensor - Green Temperature Sensor
4721021INCU II H Sensor - Humidity Sensor
4715713INCU II Pad - Placement Pad, Microfiber
4721111INCU II R Puck - Red Temperature Puck
4721039INCU II R Sensor - Red Temperature Sensor
4721000INCU II S Sensor - Sound Sensor
4721175INCU II ST Heater, Skin Temperature Heater Assembly
4721109INCU II Spacers - Tripod Spacers
4721148INCU II W Puck - White Temperature Puck
4721063INCU II W Sensor - White Temperature Sensor
4721130INCU II Y Puck - Yellow Temperature Puck
4721056INCU II Y Sensor - Yellow Temperature Sensor

Service Packages
Care PlansRequest a quote
Related Products
View related products
 
 DALE 40 Phototherapy Radiometer »
 
 INCU II Skin Temperature Heater Assembly »
 
 PS320 Fetal Simulator »
The INCU incubator analyzer and PS320 fetal heart simulator by Fluke Biomedical for neonatal device testing and safety assurance
Follow us Fluke Biomedical on Facebook Fluke Biomedical on Twitter Fluke Biomedical on YouTube Fluke Biomedical on LinkedIn Home | Site Map | Fluke Corporation | Terms and Conditions | Privacy Statement | Disclaimer © 1995 - 2017 Fluke Corporation