Test all critical ESU functions with precise power, current, frequency, crest factor and load resistance ranges

QA-ES III Electrosurgical Analyzer
QA-ES III Electrosurgery Analyzer
QA-ES III Electrosurgery Analyzer
QA-ES III Electrosurgical Generator Analyzer

QA-ES III Electrosurgical Analyzer

The QA-ES III Electrosurgical Analyzer simplifies testing to ensure the performance and safety of electrosurgical units. With generator output current accuracy as low as ± 2.5 %, the QA-ES III is capable of testing all modern high power electrosurgical units.

Collect all measurements including vessel sealing, contact quality monitor (CQM), high frequency (HF) leakage and output power distribution in single or continuous mode. The QA-ES III has all hardware and software needed for complete testing, so you don’t need to carry additional accessories or cables.

With all-in-one features, wireless functionality*, the QA-ES III is one of the most user-friendly electrosurgical analyzers on the market today. Additionally, Ansur test automation software allows users to create and automatically run tests, capture data, and produce easy-to-read reports.

10 Best Practices for Electrosurgical Unit Testing - View Whitepaper »

*Wireless capabilities not available in all countries. Ask your sales representative for more details.

QA-ES III Electrosurgical Analyzer

Features:

  • Test all critical ESU functions with precise power, current, frequency, crest factor and load resistance ranges
  • Collect measurements in single and continuous mode
  • Connect wirelessly via Bluetooth for easy record retrieval without interference or limitation by cables and wires*
  • Automatic power distribution measurement, including power, current, peak-to-peak voltage, and crest factor
  • All-in-one tool: all hardware and software necessary to complete preventive maintenance and troubleshooting is built in to the unit, eliminating the need to purchase or transport additional cables, leads, switch boxes and RECM box
  • User-friendly interface: large buttons and LCD screen guide the user through test sequences
  • Memory storage of up to 5,000 test records, eliminating the need to download data after the completion of each preventive maintenance or troubleshooting session
  • Complies to all global standards, including ANSI/ AAMI and IEC**

*Wireless capabilities not available in all countries. Ask your sales representative for more details.
**Bipolar leakage testing performed with 200 ohm fixed load.

Modes of Operation:

  • Continuous operation: Continuous measurement of power, current, peak-to-peak voltage (closed load only), and crest factor
  • Single operation: Single measurement after the set delay time of the ESU output of power, current, peak-to-peak voltage (closed load only), and crest factor
  • Power distribution: Tests impedance-sensing circuitry in “power guarantee functions in new-generation ESU. Applicable parameters – power, current, peak-to-peak voltage (closed load only) and crest factor – can easily be observed during the automatic, sequential output energy measurements.
  • RF leakage current: Provides connections and load configurations to measure HF leakage from both grounded and isolated equipment
  • RECQM: Test the “return electrode control quality monitoring using the QA-ES internal loads
Technical Specifications
Physical
Housing: Metal case
Size (HxWxL): 14.5 cm x 35 cm x 47 cm (5.75 in x 13.75 in x 18.5 in)
Weight: 7.5 kg (16.5 lbs)
Power
Power Requirements: 100 V ac, 115 V ac, 230 V ac, 50 Hz / 60 Hz, universal input
100 V/115 V: 20 VA
230 V: 30 VA
User interface
LCD: Monochrome 240 pixels x 64 pixels, 8 lines x 40 characters, white LED backlight
Keys : 6 (1 fixed, 5 soft-defined) and rotary selector knob
Environmental specifications
Operating temperature: 10 °C to 40 °C (50 °F to 104 °F)
Storage temperature: -20 °C to 60 °C (-4 °F to 140 °F)
Humidity: 10 % to 90 % non-condensing
Altitude: 2000 m maximum
IP rating: IEC60529:IP20
Electromagnetic Compatibility (EMC)
IEC 61326-1:
Basic Emissions Classification:
IEC CISPR11: Group 1, Class A. Group 1 have intentionally generated and/or use conductively coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself. Class A equipment is suitable for use in nondo¬mestic locations and/or directly connected to a low-voltage power supply network
USA (FCC):

Intentional Radiators

This device complies with part 15 of the FCC Rules. Operation is subject to the follow¬ing two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. (15.19) Changes or modifications not expressly approved by Fluke could void the user’s authority to operate the equipment. (15.21)
Safety
IEC 61010-1: Overvoltage category II, pollution degree 2
IEC 61010-2-030: Measurement 5,000 V
Wireless module listing
FCC (United States) compliant (Class A): FCC ID: X3ZBTMOD3
IC (Industry Canada) compliant: IC: 8828A-MOD3
CE (European) certified: CE0051
Measurements and tests specifications
Measures: Cut and coag waveforms, monopolar and bipolar outputs
Power and current measurements: True RMS
Bandwidth: 30 Hz to 5 MHz at -3 dB including loads
Delay time for single measurements: 0.2 seconds to 4.0 seconds from Foot Switch activation to start of measurement
Duty cycle
Variable load: 10 seconds on, 30 seconds off, at 100 W, all loads
Fixed 200 Ω load: 10 seconds on, 30 seconds off, at 400 W
Generator output measurements
Load resistance
Variable: 0 Ω, 10 Ω, 20 Ω, 25 Ω to 2500 Ω (by 25 Ω), 2500 Ω to 5200 Ω (by 100 Ω)
Accuracy: ±2.5 %
Power
(0.0 W to 99.9 W ±5 % + 1W), 100 W to 500 W ±5 %
Maximum:
At 25% duty cycle (10 seconds on, 30 seconds off):
10 Ω: 300 W,
20 Ω to 2900 Ω: 400 W,
3000 Ω to 5200 Ω: 200 W
At 10% duty cycle (5 seconds on, 45 seconds off): 10 Ω: 300 W,
20 Ω to 2400 Ω: 500 W,
2425 Ω to 2900 Ω: 400 W,
3000 Ω to 5200 Ω: 200 W
Current
RMS: 0 mA to 5,500 mA
Accuracy: ±(2.5 % of reading + 1 mA) 
Voltage
Peak: 10 kV Peak to Peak
Accuracy: ±(10 % of reading + 50 V)
Crest factor: 1.4 to 16.0
Defined as the ratio of Peak voltage to RMS voltage (Vpk /Vrms), using the larger of the 2 peaks (positive or negative)
Vessel sealing measurement
Loop current, RMS: 0 mA to 5500 mA
Accuracy: ±(2.5 % of reading + 1mA) 
HF leakage current
Fixed load: 200 Ω
V Accuracy: ±2.5 %
Power rating: 400 W
Additional fixed load: 200 Ω
Current, RMS: 0 mA to 5500 mA
Accuracy: ±(2.5 % of reading + 1 mA)
CQM test
(Contact Quality Monitor):
Resistances: 0 Ω to 475 Ω (by 1 Ω)
Accuracy: 0 Ω to 10 Ω ±0.5 Ω, 11 Ω and above ±5 %
Power rating: 0.5 W
Auto time interval: 1 to 5 seconds
Oscilloscope Output
  1 V per ampere of input current, typical
Footswitch simulations
  Cut and Coag
Communications
USB device port: Micro B connector, full speed
Wireless port: 802.15, Speed: 115,200 baud
Memory
Test records: 5,000
Non-volatile: retained through power cycling
Calibration
Recommended cycle: Traceable to the International System of Units (SI) through the appropriate National Metrology Institutes such as NIST or through intrinsic standards.
Model NameDescription
QA-ES MK IIIQA-ES MK III Electrosurgery analyzer, US
Part #4502257

Standard accessories included with the QA-ES III:


• ESU dispersive safety lead (part# 4635167)
• ESU CQM safety lead (part# 4635171)
• Safety retractable lead, 40 inch, blue (part# 4635180)
• Safety retractable lead, 40 inch, yellow (part# 4635198)
• Safety retractable lead, 40 inch, green (part# 4635209)
• Safety retractable lead, 20 inch, black (part# 4635211)
• Safety retractable lead, 20 inch, red (part# 4635227)
• Safety retractable lead, 40 inch, black (part# 4635230)
• AC285 large alligator clips, black, red (part# 1610159)
• Jumper safety lead (part# 2772209)
• Safety retractable lead, 40 inch, black, red (2) (part# 2772159)
• Micro USB cable, 2 m (part# 4114833)
• Multi-stacking 4mm banana plug patch cord, 2 m (part# 4605232)
• RECM alarm disabling lead (part# 4635253)
• Bipolar activation lead (part# 4635266)
• Ansur Plug-in software (TA versions only)
• Power cord

Optional accessories


• International dispersive lead (1/4 inch phono plug) (part# 4635248)
• Test probe set - 0.080 brass tip (part# 1909216)
• Ansur Plug-In (part# 4704312)
• Pelican Hard Case (part# 4840263)
QA-ES MK III-01QA-ES MK III Electrosurgery analyzer, SCHUKO
Part #4530503
QA-ES MK III-02QA-ES MK III Electrosurgery analyzer, UK
Part #4530515
QA-ES MK III-03QA-ES MK III Electrosurgery analyzer, Japan
Part #4530526
QA-ES MK III-04QA-ES MK III Electrosurgery analyzer, Australia
Part #4530532
QA-ES MK III-05QA-ES MK III Electrosurgery analyzer, Brazil
Part #4530544
QA-ES MK III-06QA-ES MK III Electrosurgery analyzer, US, non-wireless
Part #4632363
QA-ES MK III-07QA-ES MK III Electrosurgery analyzer, SCHUKO, non-wireless
Part #4632374
QA-ES MK III-08QA-ES MK III Electrosurgery analyzer, UK, non-wireless
Part #4632388
QA-ES MK III-09QA-ES MK III Electrosurgery analyzer, Japan, non-wireless
Part #4632395
QA-ES MK III-10QA-ES MK III Electrosurgery analyzer, Australia, non-wireless
Part #4632407
QA-ES MK III-11QA-ES MK III Electrosurgery analyzer, Brazil, non-wireless
Part #4632418
QA-ES MK III-12QA-ES MK III Electrosurgery analyzer, Brazil, 230
Part #4634398
QA-ES MK III-13QA-ES MK III Electrosurgery analyzer, Brazil, 230, non-wireless
Part #4634405
TA-QA-ES MK IIIQA-ES MK III Electrosurgery analyzer, US, with Ansur Automation Software
Part #4680301
TA-QA-ES MK III 01QA-ES MK III Electrosurgery analyzer, SCHUKO, with Ansur Automation Software
Part #4680644
TA-QA-ES MK III 02QA-ES MK III Electrosurgery analyzer, UK, with Ansur Automation Software
Part #4680807
TA-QA-ES MK III 03QA-ES MK III Electrosurgery analyzer, Japan, with Ansur Automation Software
Part #4680818
TA-QA-ES MK III 04QA-ES MK III Electrosurgery analyzer, Australia, with Ansur Automation Software
Part #4680829
TA-QA-ES MK III 05QA-ES MK III Electrosurgery analyzer, Brazil, with Ansur Automation Software
Part #4680834
TA-QA-ES MK III 06QA-ES MK III Electrosurgery analyzer, US, non-wireless with Ansur Automation Software
Part #4680841
TA-QA-ES MK III 07QA-ES MK III Electrosurgery analyzer, SCHUKO, non-wireless with Ansur Automation Software
Part #4680852
TA-QA-ES MK III 08QA-ES MK III Electrosurgery analyzer, UK, non-wireless with Ansur Automation Software
Part #4680865
TA-QA-ES MK III 09QA-ES MK III Electrosurgery analyzer, Japan, non-wireless with Ansur Automation Software
Part #4680876
TA-QA-ES MK III 10QA-ES MK III Electrosurgery analyzer, Australia, non-wireless with Ansur Automation Software
Part #4680883
TA-QA-ES MK III 11QA-ES MK III Electrosurgery analyzer, Brazil, non-wireless with Ansur Automation Software
Part #4680890
TA-QA-ES MK III 12QA-ES MK III Electrosurgery analyzer, Brazil, 230, with Ansur Automation Software
Part #4680909
TA-QA-ES MK III 13QA-ES MK III Electrosurgery analyzer, Brazil, 230, non-wireless with Ansur Automation Software
Part #4680911

Carrying Cases
QA-ES MK III CASEQA-ES III Pelican Hard Case (part# 4840263)

Service Packages
Care PlansRequest a quote
Related Products
View related products
 
 Ansur QA-ES Plug-In license »
 
 QA-ES III Pelican Hard Case »
 
 RF303RS Electrosurgery Analyzer »
Test the Covidien ForceTriad Generator with QA-ES III Electrosurgical Analyzer
MDQA Webinar
Follow us Fluke Biomedical on Facebook Fluke Biomedical on Twitter Fluke Biomedical on YouTube Fluke Biomedical on LinkedIn Home | Site Map | Fluke Corporation | Terms and Conditions | Privacy Statement | Disclaimer © 1995 - 2017 Fluke Corporation