TNT 12000 X-Ray Test Tools

 TNT 12000 X-Ray Test Tools. Radiation Monitor. Radiation dosimeter.
The TNT 12000 X-Ray Test Tools system is the newest and most comprehensive family of instruments available for assuring quality and safety of diagnostic x-ray imaging systems. With selection of all-in-one-exposure solid-state detector, dosimeter, ion chambers, optional mA/mAs invasive shunt or non-invasive clamp device, and choice of handheld display or laptop interface (both completely wireless), the TNT 12000 X-Ray Test Tools provide state-of-the-art solutions for any x-ray safety and analysis test protocol. A long battery life ensures uninterrupted operation all day.

The 12000WD solid-state detector sets up in seconds and measures kVp, radiation dose, dose rate, time, and half value layer (HVL) in a single exposure. The companion TNT 12000 DoseMate dosimeter and ion chambers provide precision dose and dose-rate measurement of radiographic, dental, fluoroscopic, and CT imaging systems. The wireless ZigBee® interface allows for quick testing and reporting, and at less than 1 mW power is preferred over Bluetooth® in medical settings where interference with delicate patient monitoring and treatment equipment may be a concern.

TNT 12000WD Wireless Detector
Featuring all-in-one-exposure measurements and ZigBee wireless communication combined with the rugged, reliable, and accurate design that is a Fluke trademark, the TNT 12000WD is a new breed of non-invasive x-ray test tool. Its compact design enhances portability and wireless operation ensures setup in seconds.

Because the TNT 12000WD measures all parameters with every exposure, there is no need for complicated menu selection, further enhancing user productivity. TNT 12000WD always defaults to the last use when powered on, so when used often for repetitive procedures it is truly a one-button (power on) solution. TNT 12000WD has the expanded functionality needed for modern applications and can be managed with minimum keystrokes. Users can identify and select custom measurement protocols and save them for future use. Full test automation and documentation software is available for TNT 12000WD, creating the advantage of accurate, repeatable testing processes.

TNT 12000 DoseMate dosimeter
The TNT 12000 DoseMate with ion-chambers provides the precision dose measurements needed for absolute dose measurement integrity. Offering customizable measurement protocols, the DoseMate dosimeter provides comprehensive, repeatable testing for radiographic, dental, fluoroscopic, and CT imaging systems in just a few keystrokes. The TNT 12000 DoseMate is compatible with existing Triad and NERO external ion chambers, offering the newest dosimeter technology with minimum investment.

mA/mAs measurement
Integrated mA/mAs measurement capability is available with both the TNT 12000WD and the TNT 12000 DoseMate. A mA/mAs-standard invasive shunt or optional non-invasive clamp device are available to meet the challenges of mAs measurement with all types of x-ray systems. ZigBee wireless interface delivers measured results to the user’s choice of handheld display or laptop, integrating all QA measurements on a single readout.

TNT 12000D Wireless Display
The TNT 12000D Wireless Display has been specifically designed with user productivity in mind and displays all measured results, as well as identification information, battery level, calibration date and more. ZigBee wireless interface from the test device offers targeted communication to the mating display for speedy results reading up to 100 feet from the test device. Wireless communication and intelligent device interface allows the user to perform multiple exposures without leaving the radiation-shielded area, thus allowing complete test protocols to be performed with minimum travel between operator and test device. Low power requirements for ZigBee interface allow for extensive battery life as compared to Bluetooth test devices, which require frequent recharging from inefficient power drain.

Ansur Test Automation Software
Test automation software allows preventative maintenance routines to be tightly controlled and consistently reported while directing users through prescribed test protocols with simple and efficient instruction. Test standardization minimizes human error and alleviates training requirements with step-by-step instruction. Photos, drawings and instructional visual aids included in test protocols negate the need to carry bulky service manuals for complicated PM procedures. Professional electronic reporting and database/CMMS interface allows for total PM and service data management.

x-ray dosimeter and ion chamer test tools
  • Choice of all-in-one detector, dosimeter, integral ma/mAs and handheld display or user’s own laptop interface.
  • 100 % ZigBee wireless operation
  • Compact handheld design
  • Sets up in seconds
  • Displays all values in one shot (all-in-one detector)
  • Simple user interface
  • Unbeatable ruggedness for long-term reliability
  • 40 kHz kV sampling rate to ensure accuracy with the most difficult applications (TNT 12000WD)
  • Global support network delivering prompt service and peace of mind to Fluke Biomedical customers worldwide

TNT 12000 X-Ray Test Tools

 

Physical Specifications
Display
320 X 240 Color LCD
Size (WxDxH)
TNT 12000D Display 6.1 in x 4.5 I x 1.6 in
TNT 12000WD Wireless Detector 6.7 in x 4.5 in x 1.75 in
TNT 12000 DoseMate Dosimeter 6.7 in x 4.5 in x 1.75 in
Weight
TNT 12000D Display 0.422 kg (0.93 lb)
TNT 12000WD Wireless Detector 1.5 lb
TNT 12000 DoseMate Dosimeter 1.1 lb

 

Electrical Specifications
Battery
Type Lithium-Ion, 3.7 V, 4000 mAh
Charge time Approximately 5 hr
Operating duration Approximately 8 hr minimum
AC adapter
Input voltage 100 V ac to 240 V ac
Input frequency 50/60 Hz
Input current 0.5 A (rms)
Output voltage 6 V dc

 

Environmental Specifications
Operating Temperature
0 ºC to 35 ºC (32 ºF to 122 ºF)
Storage Temperature
-35 ºC to 50 ºC (-31 ºF to 122 ºF)
Operating Humidity
20 % to 80 % RH (non-condensing)

 

Measurements
kVp
Units kVp Average (average of peaks during a specified interval)
kVp Max (highest peak during a specified interval)
PPV (peak practical voltage)
Ranges Radio/Fluoro modes: 40 kV to 150 kV
Mammo modes:
Mo/Mo: 22 kV to 35 kV (standard calibration)
Rh/Rh: 25 kV to 49 kV (optional calibration)
Mo/Rh: 22 kV to 40 kV (optional calibration)
Mo/Al: 22 kV to 49 kV (optional calibration)
Rh/Al: 22 kV to 49 kV (optional calibration)
W/Rh: (optional calibration)
W/Ag: (optional calibration)
Resolution 0.1 kV
Accuracy Radio/Fluoro modes: ± 2 % or ± 1 kV, whichever is greater
Mammo modes: ± 2 % or ± 0.7 kV, whichever is greater
Reproducibility ± 1 % (std of 5 readings)
Filtration correction range Radio/Fluoro modes: 1 mm Al to 10 mm Al or equivalent
Mammo mode: 0 mm Al to 0.4 mm Al added filtration
Dose/Exposure
Units Roentgens, Grays
Range 0.5 mR to 999 R
5 µGy to 999 Gy
Resolution 1 µR
0.01 µGy
Accuracy ± 5 %
Reproducibility ± 0.5 % (std of 5 readings)
Filtration correction range Radio/Fluoro modes: 1 mm Al to 10 mm Al or equivalent
Mammo modes: 0 mm Al to 0.4 mm Al added filtration
kV correction range Radio/Fluoro modes: 40 kV to 150 kV
Mammo modes: Mo/Mo: 22 kV to 35 kV
Dose/Exposure Rate
Units Roentgens or Grays per hour, minute, second, pulse
Range 8 mR/s to 10 R/s
70 µGy to 100 mGy/s
130 µR/pulse to 160 mR/pulse (@ 60 PPS)
1.2 µGy/pulse to 1.4 mGy/pulse (@ 60 PPS)
Resolution 1 µR/s
0.01 µGy/s
0.02 µR/pulse (@ 60 PPS)
0.2 n Gy/pulse (@ 60 PPS)
Accuracy ± 5 %
Filtration Correction Range Radio/Fluoro Modes: 1 mm Al to 10 mm Al or equivalent
Mammo Mode: 0 mm Al to 0.4 mm Al added filtration
kV Correction Range Radio/Fluoro Modes: 40 kV to 150 kV
Mammo Mode: Mo/Mo: 22 kV to 35 kV
Exposure Time–Radiographic Modes
Units Milliseconds, pulses
Range Range (@ stated accuracy) Milliseconds: 1.0 ms to 9999 ms
Pulses: 1 pulse to 999 pulses
Resolution Milliseconds: 0.1 ms
Pulses: 1 pulse
Accuracy Milliseconds: 1 % or 0.5 ms from 10 to 9999 ms
Milliseconds: 10% or 0.5ms from 1.0 to 9.9 ms
Pulses: ± 1 pulse
Reproducibility Milliseconds: 1 % or 0.5 ms from 10 to 9999 ms
Milliseconds: 10% or 0.5 ms from 1.0 to 9.9 ms
Pulses: ± 1 pulse
Elapsed Time–Fluoro Modes
Range 10 sec to 9999 sec
Resolution 0.1 second
Accuracy 1 % or 0.5 sec
Average Pulse Rate – Pulsed Fluoro
Range 1 pps to 999 pps (pulses per second)
Resolution 1 pps
Accuracy 1 pps
Average Pulse Width – Pulsed FLuoro
Range 10 ms to 999 ms
Resolution 0.1 ms
Accuracy 1 % or 0.5 ms
HVL
Range Radio/Fluoro modes: 1.2 mm Al to 10 mm Al (equivalent)
Mammo mode: 0.2 mm Al to 0.6 mm Al (equivalent)
Resolution Radio/Fluoro modes: 0.1 mm Al (equivalent)
Mammo mode: 0.01 mm Al (equivalent)
Accuracy Radio/Fluoro modes: ± 10 % or 0.2 mm Al (equivalent)
Mammo mode: ± 5 % or 0.05 mm Al (equivalent)

TNT 12000 DoseMate Dosimeter Specifications

 

Accuracy
Exposure and Exposure Rate Accuracy
± 1 % of reading ± 2 range resolution steps over range of 18 °C to 28 °C and ± 2 % of reading ± 2 range resolution steps over the full operating temperature range of 0 °C to 50 °C
3 % NIST-traceable calibration is provided with each system and includes effects of 96035B, and 96020C

 

Measurement Modes
Dose
Autoranging across five decades of sensitive ranges
Automatic drift and offset compensation
Automatic post-exposure display hold
Rate
Measurement range covers a span from low-level image intensifier measurements to unattenuated, direct beams
Automatic offset compensation and nonlinear filtering
Autoranging provides five decades of sensitivity ranges
Display updates once per second

 

Low Rate Mode
This mode is only for making very low dose rate measurements. Nonlinear digital filtering and autoranging provide five decades of sensitivity ranges. Display updates once per second. In this mode, automatic current offset and drift compensation are disabled. As a result, the system can display very low dose rates

 

Power Requirements
Bias Voltage Supply
Fixed electronic bias (~300 V)
Bias voltage removed from triaxial input connector at instrument turnoff

 

Connections
Ion Chamber Input
Triax, BNC
Collector and guard positive-biased relative to ion chamber body and service dosimeter chassis
Power
Same as TNT 12000WD

 

General Information
Display
Wireless ZigBee or optional USB interface to TNT 12000 display indicates all ion chamber identification information, numerical measurement results, battery level, calibration date, and other information
Weight
˜ 0.68 kg (1.5 lb)
Dimensions (maximum) (WxDxH)
15.2 cm x 11.4 cm x 4.45 cm
(6 in x 4.5 in x 1.75 in)

96020C and 96035B Diagnostic Ion Chambers

 

Technical Specifications
Energy Range
96020C 30 kVp to 150 kVp
96035B 30 kVp to 150 kVp for diagnostic measurements
20 kVp to 50 kVp for mammographic measurements
Nominal Volume
96020C 150 cm3; 11.30 cm diameter by 1.5 cm thick active volume
96035B 15 cm3; 3.96 cm diameter by 1.22 cm thick active volume
Nominal Sensitivity
96020C H60: 2.08 R/C x 107 R/C at 22 °C and 760 mmHg (optimized for low-level image intensifier and cine measurements)
96035B L100: 2.0 R/C x 108 R/C at 22 °C and 760 mmHg
MV30 (PTB Mammo Point)
96020C/96035B 2.21 R/C x 108 R/C at 22 °C and 760 mmHg (flat energy response suitable for conventional diagnostic radiography and mammography)
Leakage Current
96020C/96035B < 10 fA under normal bias conditions (300 V)
Collection Efficiency
96020C 95 % at 2,000 R/min
96035B 95 % at 5,000 R/min
Wall Material
96020C Composite graphite-filled thermoplastic
96035B Graphite-coated acrylic (methylmethacrylate)
Window Material
96020C 0.76 mm thick, graphite-coated polycarbonate
96035B Both entrance windows are made of 0.25 mm graphite-coated polycarbonate
Window Density
96020C 91 mg/cm2
96035B 32 mg/cm2
Active Window Area
96020C 100 cm2, centered within the chamber body
96035B Each side of the chamber has a circular active window region centered 7.1 mm further from the BNC connector than the center of the chamber body; active window regions have an area of 12.32 cm2
Collector Plate
96020C 0.8 mm thick graphite-coated acrylic plate, 10.80 cm in diameter; 2.16 cm x 2.85 cm guard region electrically isolated from collector area
96035B 0.25 mm thick, centrally mounted, graphite-coated, polycarbonate plate, 3.18 cm, ± 0.01 cm in diameter; 1.27 cm x 0.89 cm guard region is electrically isolated from the collector area
Connector
96020C/96035B Side-mounted, triaxial, two-lug BNC connector
Calibration
96020C Standard calibration performed at H60 (NIST defined as 60 kVp, first HVL of 6 mm Al, homogeneity coefficient of 94)
96035B Standard calibration performed at one diagnostic and one mammographic beam quality
Calibration factors normalized to 22 °C and 760 mmHg Diagnostic Unattenuated Beam
Calibration on diagnostic side of chamber is performed at M80 (NIST defined as 80 kVp, first HVL of 2.97 mm Al, homogeneity coefficient of 57) Mammographic Beam
Calibration on mammographic side performed at Mo/Mo28 (NIST defined as 28 kVp, first HVL of 0.332 mm Al, homogeneity coefficient of 74.3) or MV30 (PTB defined as 30 kVp, first HVL of 0.337 mm Al)

mA/mAs Specifications

 

Measurement Range
Invasive mAs (With Shunt) mA/mAs Ranges*
Min to Max 0.00 to 99.99
100.0 to 999.9
1000 to 1999

*mAs measurements are fully
auto-ranging, so values
are display ranges only
Non-Invasive mAs (with clamp) mA/mAs Ranges
Min to Max 0.0 to 999.9
1000 to 3999

 

Accuracy
Invasive mAs (With Shunt)
± 1 %
Model NameDescription
TNT 12000WD Wireless Detector + Display TNT 12000WD Wireless Detector + TNT 12000D Display (Item # 3335763)

Includes:

  • TNT 12000WD Wireless Detector (Item # 3345931)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • ZigBee USB Dongle (Item # 3341333)
  • Customized Carrying Case (Item # 3346011)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
  • Quick Start Reference Guide (Item # 3557133)
TNT 12000WD Wireless Detector TNT 12000WD Wireless Detector (Item # 3335774)

Includes:

  • TNT 12000WD Wireless Detector (Item # 3345931)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • ZigBee USB Dongle (Item # 3341333)
  • Customized Carrying Case (Item # 3346011)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
  • Quick Start Reference Guide (Item # 3557133)
TNT 12000D Wireless Display TNT 12000D Wireless Display (Item # 3335795)

Includes:

  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • ZigBee USB Dongle (Item # 3341333)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
TNT 12000WD Wireless Detector with mAs + DoseMate + Display TNT 12000WD Wireless Detector with mAs + TNT 12000 DoseMate + TNT 12000D Display (Item #3586807)

Includes:

  • TNT 12000WD Wireless Detector with mAs (Item # 3586570)
  • TNT 12000 DoseMate Dosimeter (Item # 3561890)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male to Male, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490 )
  • mA Cable Assembly, BNC, male to female (Item # 1918780 )
TNT 12000WD Wireless Detector + DoseMate with mAs + Display TNT 12000WD Wireless Detector + TNT 12000 DoseMate with mAs + TNT 12000D Display (Item #3586829)

Includes:

  • TNT 12000WD Wireless Detector (Item # 3345931)
  • TNT 12000 DoseMate Dosimeter with mAs (Item # 3586543)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male to Male, BNC, 6 ft (Item #3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
TNT 12000WD Wireless Detector with mAs + Display TNT 12000WD Wireless Detector with mAs + TNT 12000D Display (Item # 3586787)

Includes:

  • TNT 12000WD Wireless Detector with mAs (Item # 3586570)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • ZigBee USB Dongle (Item # 3341333)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
  • mA Shunt Assembly (Item # 3586555)
  • Connector, BNC (female) to Binding Posts (Item # 1938315)
  • Connector, BNC (female) Double Banana Plug (Item # 1633042)
  • Customized Carrying Case (Item # 3586865)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
TNT 12000 DoseMate with mAs + Display TNT 12000 DoseMate with mAs + TNT 12000D Display (Item # 3586779)

Includes:

  • TNT 12000 DoseMate Dosimeter with mAs (Item # 3586543)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Plug, Connector, Triax (Item # 3551210)
  • Triax Cable, Male toMale, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
  • mA Shunt Assembly (Item # 3586555)
TNT 12000WD Wireless Detector + DoseMate + Display TNT 12000WD Wireless Detector + TNT 12000 DoseMate + TNT 12000D Display (Item # 3586841)

Includes:

  • TNT 12000WD Wireless Detector (Item # 3345931)
  • TNT 12000 DoseMate Dosimeter (Item # 3561890)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male to Male, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Customized Carrying Case (Item # 3586528)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
  • Quick Start Reference Guide (Item # 3557133)
TNT 12000 DoseMate + Display TNT 12000 DoseMate + TNT 12000D Display (Item # 3586754)

Includes:

  • TNT 12000 DoseMate Dosimeter (Item # 3561890)
  • TNT 12000D Wireless Display (Item # 3345954)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male toMale, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Customized Carrying Case (Item # 3586528)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
TNT 12000WD Wireless Detector with mAs + DoseMate TNT 12000WD Wireless Detector with mAs + TNT 12000 DoseMate (Item # 3586818)

Includes:

  • TNT 12000WD Wireless Detector with mAs (Item # 3586570)
  • TNT 12000 DoseMate Dosimeter (Item # 3561890)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male toMale, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
  • mA Shunt Assembly (Item # 3586555)
  • Connector, BNC (female) to Binding Posts (Item # 1938315)
TNT 12000WD Wireless Detector + DoseMate with mAsTNT 12000WD Wireless Detector + TNT 12000 DoseMate with mAs (Item # 3586852)

Includes:

  • TNT 12000WD Wireless Detector (Item # 3345931)
  • TNT 12000 DoseMate Dosimeter with mAs (Item # 3586543)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male to Male, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
  • mA Shunt Assembly (Item # 3586555)
  • Connector, BNC (female) to Binding Posts (Item # 1938315)
  • Connector, BNC (female) Double Banana Plug (Item # 1633042)
  • Customized Carrying Case (Item # 3586528)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
  • Quick Start Reference Guide (Item # 3557133)
TNT 12000WD Wireless Detector + DoseMate TNT 12000WD Wireless Detector + TNT 12000 DoseMate (Item # 3586834)

Includes:

  • TNT 12000WD Wireless Detector (Item # 3345931)
  • TNT 12000 DoseMate Dosimeter (Item # 3561890)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male toMale, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Customized Carrying Case (Item # 3586528)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
  • Quick Start Reference Guide (Item # 3557133)
TNT 12000WD Wireless Detector with mAs TNT 12000WD Wireless Detector with mAs (Item # 3586793)

Includes:

  • TNT 12000WD Wireless Detector with mAs (Item # 3586570)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • ZigBee USB Dongle (Item # 3341333)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
  • mA Shunt Assembly (Item # 3586555)
  • Connector, BNC (female) to Binding Posts (Item # 1938315)
  • Connector, BNC (female) Double Banana Plug (Item # 1633042)
  • Customized Carrying Case (Item # 3586865)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)
  • Quick Start Reference Guide (Item # 3557133)
TNT 12000 DoseMate with mAs TNT 12000 DoseMate with mAs (Item # 3586768)

Includes:

  • TNT 12000 DoseMate Dosimeter with mAs (Item # 3586543)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048)
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male toMale, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Test Lead Kit, 1 Set of Test Leads (Item # 3555490)
  • mA Cable Assembly, BNC, male to female (Item # 1918780)
  • mA Shunt Assembly (Item # 3586555)
  • Connector, BNC (female) to Binding Posts (Item # 1938315)
  • Connector, BNC (female) Double Banana Plug (Item # 1633042)
TNT 12000 DoseMate Dosimeter TNT 12000 DoseMate Dosimeter (Item # 3588752)

Includes:

  • TNT 12000 DoseMate Dosimeter (Item # 3561890)
  • AC Adapter(s)/Charger(s) with multi-prong adapters (Item # 3346048) )
  • Cable, Type A to Mini B USB (Item # 3346027)
  • Cable, Mini A to Mini B USB (Item # 3346030)
  • Test Stand (Item # 3586537)
  • Triax Cable, Male toMale, BNC, 6 ft (Item # 3586644)
  • ZigBee USB Dongle (Item # 3341333)
  • HVL Filter Set (Item # 3264115)
  • Adapter Stem (Item # 3264091)
  • Customized Carrying Case (Item # 3586528)
  • CD-ROM, DoseMate/TNT/mAs (Item # 3586667)

Accessories
500-200500-200 CT Ion Chamber, 10cc (10cm³) (part# 2549741)
96035BDiagnostic Ionization Chamber 15 cc (part# 2550024)
96020CDiagnostic Ionization Chamber, 150cc (part# 2549992)
EM4524-C-240EM4524-C-240 mA Cable Assembly, Male to Female, BNC, 20 ft
8602086020 Triax Cable (part# 3355057)
(BNC connectors, Male to Male, 20ft)

Ion Chambers
500-100500-100 CT Ion Chamber, 3.2cc (3.2cm³) (part# 2549734)

Batteries, Chargers, and Power Supply
14-445AC Adapter/charger with multi-prong adapters (part# 3346048) for TNT 12000

Cables
50-198Cable, Mini A to Mini B USB (part# 3346030)
50-197Cable, Type A to Mini B USB (part# 3346027)

Miscellaneous Accessories
90-183Wireless USB Dongle (part# 3341333)
ZigBee

Software
ANSUR TNT 12000Ansur TNT 12000 Plug-In software (part# 3337356)

Service Packages
Care PlansRequest a quote
Biomedical Equipment  |  Patient Simulator  |  Safety Analyzer  |  Dosimeter  |  Radiation Detector
Search Fluke Biomedical
ResourcesProducts
Find Resources
Related Products
View related products
 
 10100AT TRIAD TNT Dosimeter X-Ray Field Kit »
 
 10500AMT Triad TNT X-Ray Field Service/Calibration/QA Kit »

TNT 12000 Data Sheet