|
|
|
|
|
|
|
|
|
 |
|  | |  | | |  |  | | | New! ESA615 Electrical Safety Analyzer
View the math Compare and decide Select your tester Get more information
|
|
Automated testing to the latest electrical safety standards in the palm of your hand—including new IEC62353!
The automated ESA615 performs all primary electrical safety tests, including mains (line) voltage, protective earth (ground wire) resistance, MAP (insulation) resistance, device current, and applied parts (patient leakage) tests. It also offers ECG simulation and point–to-point voltage, leakage, and resistance tests. The ESA615 is an all-in-one solution with a multimeter, electrical safety analyzer and ECG simulator in a single test instrument. |
 See an automated IEC62353 electrical safety test | |
- Automation inside
- Newest standards compliance
- Data management made easy
- Simple, multi-language user interface
We did the math: your time is valuable
| Background information |
| How many medical devices in your inventory require electrical safety testing? |
1500 |
| How many of those are tested once per year? |
1000 |
| How many of those are tested twice per year? |
400 |
| How many of those are tested three times per year? |
100 |
| How many devices per year do you test for electrical safety upon incoming inspection? |
200 |
| How many devices per year do you test electrical safety after repairs? |
50 |
| Total electrical safety tests per year |
2350 tests |
| Electronic testing |
| Average time for one manual electrical safety test |
10 minutes |
| Average time for one automated ESA615 electrical safety test |
4 minutes |
| Average per-test time savings for automated ESA615 over manual electrical safety testing |
6 minutes |
| Documentation |
| Average time to document one manual electrical safety test device results |
3 minutes |
| Time to document automated electrical safety test results with ESA615 Electrical Safety Analyzer |
1 minute |
| Average per-test documentation time savings for automated ESA615 over manual electrical safety testing |
2 minutes |
| Savings |
| ESA615 saves you: |
313 hours per year |
| At an average billable rate of $85/hour, that is an annual savings of: |
$26633.33 | |
|
 ESA615 Automated electrical safety tester
|
|
 ESA620 Complete 60601 testing
|
|
Compare and decide: find the right electrical safety tester for you
| |
ESA615 |
ESA612 |
ESA620 |
601 Pro SeriesXL |
| Basic overview |
| Preferred analyzer for which standard? |
IEC62353 and NFPA-99 |
ANSI/AAMI and NFPA-99 |
IEC60601-1 |
|
| Automation inside |
● |
|
|
● |
| Ansur compatible |
● |
● |
● |
|
| Onboard memory |
● |
● |
|
● |
| ECG Simulation |
● |
● |
● |
● |
| Multi-language selection |
● |
|
|
● |
| Wireless communication |
● |
|
|
|
| Handheld |
● |
● |
|
|
| Removable memory card |
● |
|
|
|
| GFCI Protection |
● |
● |
● |
|
| DUT Load current |
● |
● |
● |
● |
| 20 A Test capability |
● |
● |
● |
● |
| 25 A Test capability |
|
|
● |
● |
|
Selecting the right tester for you can be daunting, but most electrical safety analyzer selections come down to three simple questions.
 |
Fluke Biomedical electrical safety analyzers handle the spectrum of new electrical safety standards to maintain your medical equipment fleet
- NFPA-99
- IEC62353
- IEC60601
- ANSI/AAMI ES1: 1993
- VDE 751
- AN/NZS 3551
- IEC61010
| | |
Do you want a more in-depth product comparison, pricing, or an on-site test drive/demonstration? |
| |
|
|
|
|
|
 | | Search Fluke Biomedical | | | | | | | | | | | | | | | | | | | | | | | | Find Resources | | | | | | | | |
|
|
|
|
|
|
|
|
|
|