Fluke Biomedical - Trusted for the measurements that matter to medical industry professionals.
Home  |  Products  |  Infusion Device Analyzers  |  
This product is discontinued or reclassifiedFluke Biomedical suggests:
IDA-5 Infusion Device Analyzer

IDA 4 Plus - Infusion Pump Analyzer

4-channel iv pump analyzer

Replaced by the IDA-5 infusion device analyzer »

IDA 4 Plus iv pump analyzer
IDA 4 Plus infusion pump tester
IDA 4 Plus infusion pump tester
IDA 4 Plus infusion pump tester
IDA 4 Plus infusion pump tester

IDA 4 Plus Infusion Pump Analyzer

The IDA 4 Plus infusion pump analyzer uses fundamental measurement technology integrated with sophisticated electronics to ensure accuracy and reduce risk of human error during testing. The IDA 4 Plus iv pump analyzer maximizes productivity by testing up to four infusion pumps or channels at once, allowing you to move on to other tasks while the IDA 4 Plus takes care of testing and documentation.

The IDA 4 Plus infusion pump analyzer tests virtually any brand of infusion pump including Alaris® (Carefusion), Hospira, Baxter, Abbott, Sigma and many others. The IDA 4 Plus is compatible with a wide array of infusion devices including syringe pumps, volumetric pumps and anesthesia pumps. Our infusion device tester measures instantaneous flow, average flow, occlusion pressure, and analyzes patient-control analgesia (PCA) units. An optional PCA trigger box provides automated PCA pump control, allowing technicians to set up tests and walk away. An autostart feature simplifies syringe pump testing or other tests that have long startup times.

With built-in memory, the IDA 4 Plus records infusion pump test results internally and provides easy-to-read test-result graphs live right on the analyzer’s screen. The display is so large numbers can be read from across the room. Additionally, the IDA 4 Plus comes with Hydrograph PC software for creating full-color graphs and reports. For automated testing, the IDA 4 Plus is compatible with Fluke Biomedical’s medTester 5000C (US only).

The IDA 4 Plus comes in 1-2-3- or 4-channel configurations. This allows the option of adding up to three channels at a later time to meet the evolving needs of your work group.

Test any parameter you need with confidence.

  • Tests up to four infusion pumps simultaneously
  • Compatible with virtually any type of infusion device
  • Instantaneous and average flow measurement
  • Occlusion pressure measurements to 45 psi
  • Single- and dual-flow (piggyback) testing
  • Full PCA testing (bolus volume, lockout time, and automated external triggering)
  • Autostart mode enables unit to begin testing only when fluid is detected
  • Live graphical view for real real-time pump malfunction/problem alerts or analysis
  • Built-in memory to save test results for printing or downloading to computer
  • Hydrograph results-reporting software to display, store and recall results via PC
  • Automated testing through Fluke Biomedical medTester 5000C (US only) and IDA 4 Ansur Plug-In
  • Ability to add up to three channels for multiple, simultaneous infusion pump testing
  • Ability to create trumpet curves and test up to 12 channels simultaneously with the IDA 4 Ansur Plug-In

Specifications
Average Flow Rate Technique
 Calculated by measuring a volume over time
Range
 0.5 ml/hr to 1000 ml/hr
Accuracy
 1% of reading + 1 LSD for flows of 16-200 ml/hr for volumes over 20 ml; otherwise, 2% of reading + 1 LSD after delivery of 10 ml
Volume Measurements Technique
 Volume measured directly by the transducer in minimum sample sizes of 60 microliters
Range
 0.06 ml to 9999 ml
Accuracy
 1% of reading + 1 LSD for flows of 16 to 200 ml/hr for volumes over 20 ml; otherwise, 2% of reading ± 1 LSD after delivery of 10 ml
Minimum Bolus Volume
 0.5 ml
Maximum Bolus Count
 99
PCA Measurements Technique
 Volume is measured directly by the transducer in minimum bolus volumes of 0.5 ml. The measurement is made with a continuous rate between 0 and 30 ml/hr. The bolus flow rate should be at least four times the basal flow rate for reliable detection of boluses.
Maximum Bolus Volume
 9999 ml
Accuracy
 See volume measurement
Pressure Measurements Technique
 Direct occlusion of the infusion line and measurement of pressure prior to the glass transducer.
Range
 0 PSI to 45 PSI and equivalents in mmHg and kPa
Accuracy
 1% of full scale + 1 LSD
Back Pressure
 - 100 mmHg to + 300 mmHg
Supply Voltage
 Autoswitching to any voltage from 90 V ac to 260 V ac
Dimensions (LxWxH)
 30.2 cm x 22.9 cm x 18.1 cm
 (11.8 in x 9 in x 7.2 in)
Weight
 4.9 kg (10.8 lb)
Model NameDescription
IDA-4P/1-AUS250VIDA 4 PLUS 1-Channel Infusion Device Analyzer Australia 250 V
IDA-4P/1-DEN250VIDA 4 PLUS 1-Channel Infusion Device Analyzer Denmark 250 V
IDA-4P/1-US120VIDA 4 PLUS 1-Channel Infusion Device Analyzer US 120V (United States)

All units include the following:

  • Electronic User Manual and HydroGraph software (48459)
  • 20 ml Priming Syringe (49964)
  • Luerlock-3 Way (one for each channel) (48457FG)
  • 5’ Plastic Drain Line (76044)
  • Power cord (country specific)
  • Serial Communication Cable (75029)
IDA-4P/1-SHK250VIDA 4 PLUS 1-Channel Infusion Device Analyzer Shuko 250 V
IDA-4P/1-ISR250VIDA 4 PLUS 1-Channel Infusion Device Analyzer Israel 250 V
IDA-4P/1-ITAL250VIDA 4 PLUS 1-Channel Infusion Device Analyzer Italy 250 V
IDA-4P/1-IND250VIDA 4 PLUS 1-Channel Infusion Device Analyzer India 250 V
IDA-4P/1-SWZ250VIDA 4 PLUS 1-Channel Infusion Device Analyzer Switzerland 250 V
IDA-4P/1-UK250VIDA 4 PLUS 1-Channel Infusion Device Analyzer United Kingdom 250 V
IDA-4P/2-US120VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously United States 120 V
IDA-4P/2-AUS250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously Australia 250 V
IDA-4P/2-DEN250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously Denmark 250 V
IDA-4P/2-SHK250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously Shuko 250 V
IDA-4P/2-ISR250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously Israel 250 V
IDA-4P/2-ITAL250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously Italy 250 V
IDA-4P/2-IND250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously India 250 V
IDA-4P/2-SWZ250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously Switzerland 250 V
IDA-4P/2-UK250VIDA 4 PLUS 2-Channel Infusion Device Analyzer Full testing capability for up to 2 infusion pumps simultaneously United Kingdom 250 V
IDA-4P/3-US120VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously United States 120 V
IDA-4P/3-AUS250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously Australia 250 V
IDA-4P/3-DEN250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously Denmark 250 V
IDA-4P/3-SHK250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously Shuko 250 V
IDA-4P/3-ISR250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously Israel 250 V
IDA-4P/3-ITAL250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously Italy 250 V
IDA-4P/3-IND250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously India 250 V
IDA-4P/3-SWZ250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously Switzerland 250 V
IDA-4P/3-UK250VIDA 4 PLUS 3-Channel Infusion Device Analyzer Full testing capability for up to 3 infusion pumps simultaneously United Kingdom 250 V
IDA-4P/4-US120VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously United States 120 V
IDA-4P/4-AUS250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously Australia 250 V
IDA-4P/4-DEN250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously Denmark 250 V
IDA-4P/4-SHK250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously Shuko 250 V
IDA-4P/4-ISR250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously Israel 250 V
IDA-4P/4-ITAL250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously Italy 250 V
IDA-4P/4-IND250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously India 250 V
IDA-4P/4-SWZ250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously Switzerland 250 V
IDA-4P/4-UK250VIDA 4 PLUS 4-Channel Infusion Device Analyzer Full testing capability for up to 4 infusion pumps simultaneously United Kingdom 250 V

Adapters
6020503FG6020503FG Cable, Serial Assembly (part# 2392046)
(for use with 505 Pro Series/IDA 4 Plus)

Cables
3010-0441Interface cable, medTester to IDA 4 Plus (without wedge adapter) (RS-232; female DB9 to female DB25) (part# 2200102) (medTester to SigmaPace™1000/PC/Index 2XL/IDA 4 Plus [IDA 4 to wedge requires cable# 2201042]; Impulse 4000 to PC)
71072Parallel printer cable, D25M to C36M (part# 2238072)
3010-05983010-0598 RS232 Cable Interface (part# 2201042)
DB9F-DB25F (for use with medTester 5000C with Wedge adapter to IPT-MC/IDA 4 Plus)

Miscellaneous Accessories
48457FG48457FG Luerlock 3-way t-valve
(part# 2391750) for IDA4 Plus
4994849948 IDA chassis gasket (part# 2217210)
FACTORY SERVICE REPLACEMENT PART ONLY
49964FG49964FG Priming Syringe (part# 2391792)
(for use with IDA 4 PLUS)
7604476044 Drain Tube (part# 2238909)
Connect to rear outlet drain of IDA4 Plus
9513-0212Mini PC-Style External Keyboard (part# 2245061)
(83 keys, AT or PS/2, wedge adapter required)

Printers
60196120V Power Supply for Seiko DPU414 printer (part# 2235375)
Printer used with the following products:
•VT PLUS HF Gas Flow Analyzer
•ISA601 Pro SeriesXL
•IDA 4 Plus
•Index 2XL
•QED 6
•BP Pump 2
PRINTR/414-US120VPrinter, SEIKO DPU-414-30B (part# 2248899)
Includes 120V PWR Supply (part# 2235375)
(Note: requires additional purchase of parallel printer cable, part# 2238072)
for use with ESA601/IDA 4 Plus/Index 2XL/QED 6/BP Pump 2
PRINTR414-SHK220VPrinter, Seiko DPU-414-30B with 220 V power supply (part# 2399531)
(NOTE: requires additional purchase of serial printer cable (part# 3370513)

Software
ANSUR IDAAnsur IDA 4 PLUS Plug-In license (part# 3935677)

Service Packages
Care PlansRequest a quote
Biomedical Equipment  |  Patient Simulator  |  Safety Analyzer  |  Dosimeter  |  Radiation Detector
Related Products
View related products
 
 Ansur IDA-4 PLUS Plug-In license »
 
 IDA-1S Infusion Device Analyzer »
 
 IDA-5 Infusion Device Analyzer »
Follow us Fluke Biomedical on Facebook Fluke Biomedical on Twitter Fluke Biomedical on YouTube Fluke Biomedical on LinkedIn Home | Site Map | Fluke Corporation | Terms and Conditions | Privacy Statement | Disclaimer © 1995 - 2016 Fluke Corporation