Fluke Biomedical - Trusted for the measurements that matter to medical industry professionals.
Home  |  Products  |  FB-SIMS  |  Non-Invasive Blood Pressure Simulators  |  
This product is discontinued or reclassifiedFluke Biomedical suggests:
ProSim 8 Vital Signs Patient Monitor Simulator

CuffLink NIBP Simulator

 CuffLink NIBP Simulator

CuffLink NIBP Simulator

The CuffLink NIBP simulator offers a quick, reliable, and consistent way to evaluate the operation and performance of oscillometric NIBP signals.

With user-programmable selections, the CuffLink NIBP simulator will test the full range or normal, hypertensive, and hypotensive dynamic waveforms representing typical adult, infant, and neonatal patients. The analyzer can also generate normal, bradycardia, and tachycardia rhythm selections with a wide range of weak, normal, and strong peripheral pulses. A variety of parameters allow creation and storage of five custom autosequences within the unit. In addition to the programmable target values, these autosequences can include static pressure, leak, and over-pressure relief valve “pop-off tests.

CuffLink features an internal compressor, automating the static pressure measurements, leak testing, and relief-valve testing. Setting and adjusting cuff pressure levels is easy and provides consistent cuff-inflation levels for the tests.

Standard Features

 

  • Dynamic oscillometric non-invasive BP simulation
  • Automated static-pressure measurements, leakage testing, and relief-valve testing
  • Five automated autosequences
  • Five arrhythmia selections
  • Adult and neonatal selections
  • Adjustable heart rate values
  • Direct interface with medTester 5000C
Specifications
Power
120/250 V ac, 50 W average, 100 W peak, 50/60 Hz
Analog Outputs
Cuff Pressure: 0 mmHg to 499.95 mmHg FS ± 1.0 % of reading, 10 mV/mmHg
Pulse Pressure: 0.0 mmHg to 5.0 mmHg FS ± 1.0 of reading, 1.0 V/mmHg
Digital Manometer
Pressure Range: - 499.75 mmHg to 499.75 mmHg
Measurement Parameters: instantaneous and peak
Displayed Graphics
Dynamic real-time NIBP cuff-pressure waveform programmed peripheral pulse and envelope waveforms
Display
Alphanumeric Graphic Display (LCD)
Alphanumeric Mode: 8 lines x 40 characters
Graphics Mode: 64 vertical x 240 horizontal dot matrix, backlight with viewing angle adjustment
Digital Interfaces
RS-232/Serial: bidirectional. Downloads cuff measurement data and controls test features with a compatible computer or via the medTester 5000C with the medCheck option.
Parallel Printer: Centronics compatible
Pulse Sync: 0 V dc to 5 V dc (TTL)
Cuff Mandrel
Interlocking Plastic Blocks: four cuff circumferences, including 39.5 cm (large adult), 33 cm (adult), 26.6 cm (small adult) and 20 cm (child); maximum cuff : 15.25 cm.
Truncated Plastic Cylinders: Three neonatal cuff circumferences, including 14 cm, 10 cm, and 7.6 cm; maximum cuff width of 7.6 cm.
Pop-off Valve Testing
Automatic test for operation of the monitor’s relief valve
Measurement Parameters: instantaneous and peak pressure
Maximum Pressure: 499.75 mmHg
System Leak Testing
Start Pressure: 499.75 mmHg max
Elapsed Time: 60 s (fixed)
Leak-Rate Range: 0.25 mmHg/min to 499.75 mmHg/min
Pump: 2 liters/minute minimum (free flow)
Accuracy
Dynamic NIBP Response Repeatability (Systolic/Diastalic/Mean): ± 1 % of target value
Cuff Pressure: ± 1 % of reading ± 1 mmHg
Input Overpressure Limit: ± 1500 mmHg
Autosequences
Up to five user-programmable sequences to test non-invasive BP monitors with a specific series of CuffLink performance tests, including static pressure test, leak test, and pop-off test
Up to eight adult-neonatal-arrhythmia dynamic non-invasive BP selections, each of which can be cycled up to 99 times during the sequence.
Printable test report.
Displayed Real-Time Parameters
Instantaneous Cuff Pressure: 0 mmHg to 300 mmHg
Peak Cuff Pressure: 0 mmHg to 500 mmHg peak
Inflate/Deflate Time: 0.1 s to 999.9 s
Inflate/Deflate Rate: 0.1 mmHg/s to 999.9 mmHg/s
Total Measurement Time: 0 s to 999.9 s max
Selected Heart Rate: selected systolic/diastolic (mean) target values
User-programmed vertical and horizontal shifts
Dynamic Noninvasive Blood Pressure
Simulation of a range of normal, hypertensive and hypotensive dynamic noninvasive BP for typical adult, infant, and neonatal patients. Generation of normal, bradycardia, and tachycardia rhythm selections with a wide range of user-programmable peripheral pulse amplitudes (weak, normal and strong). Compatible with oscillometric non-invasive BP devices.
Preprogrammed Target Value Selections: Adult Systolic/Diastolic (MAP) (mmHg): 60/30 (40), 80/50 (62), 100/65 (75), 120/80 (90), 150/100 (115), 200/150 (165) and 255/195 (215)
Neonatal/Pediatric Systolic/Diastolic: - Above selections, excluding 255/195 and 200/150
Repeatability: ± 1 % of selected target value
Adult Arrhythmia Selections: Baseline Target Value: (120/80) (NSR)
Atrial fibrillation (A-Fib)
Premature atrial contraction (PAC)
Premature ventricular contraction (PVC)
Missed beat (MB)
Aberrant sinus conduction (AS)
Preprogrammed Peripheral Pulse Waveforms: Pulse amplitude at MAP: 2.0 mmHg (typical adult value)
Pulse volume range: 0.0 to 5.1 ml
Pulse rise time: 80 ms (min)
Heart rates (adult & neonate): 30, 40, 60, 80, 120, 160, 200 & 240 BPM
Heart-rate accuracy: ± 1.0 % of selected rate
User-Programmable Target Value Shifts: Horizontal Axis: preprogrammed target value selections shifted in 1.0 mmHg steps over a maximum range of ± 100 mmHg to increase or decrease dynamic pressure values
Vertical Axis: relative amplitude shifted in 1 % increments over a maximum range from 0 to 200 % to simulate weak, normal, and strong peripheral pulses
Environmental
Operating temperature: 15 ºC to 35 ºC (59 ºF to 95 ºF)
Storage temperature: 0 ºC to 50 ºC (32 ºF to 122 ºF)
Dimensions (WxDxH):
31.75 cm x 38.1 cm x 12.7 cm
(12.5 in x 15 in x 5 in)
Weight
6.82 kg
(15 lb)
Model NameDescription
CUFFLINK-US120VCuffLink Non-Invasive Blood Pressure Analyzer – US 120 V (item#2246985), includes:
  • Operating manual (item#2242915)
  • Adult Cuff Mandrel Spacer Blocks (item#2392381)
  • Adult Cuff Mandrel End Blocks (qty 2) (item# 2230305)
  • External Cuff Mandrel Neonatal (truncated plastic cylinder diameters: 7, 6, 10, and 14 cm) (item#2392328)
  • CuffLink Adapter Kit (item#2245300)
  • Hospital Grade Power Cord Set (item#country specific)
  • Soft Vinyl Accessory Pouch (item#2248408)
CUFFLINK-AUS250VCuffLink– Australia 250 V (item#2399820)
    CUFFLINK-DEN250VCuffLink Denmark 250 V (item#2399835)
    CUFFLINK-IND250VCuffLink India 250 V (item#2399873)
    CUFFLINK-ISR250VCuffLink Israel 250 V (item#2399858)
    CUFFLINK-ITAL250VCuffLink Italy 250 V (item#2399864)
    CUFFLINK-SHK250VCuffLink Schuko 250 V (item#2399847)
    CuffLink-SWZ250VCuffLink Switzerland 250 V (item#2399886)
    CuffLink-UK250VCuffLink United Kingdom 250 V (item#2399899)

    Adapters
    9503-0019FGCuff/Hose Adapter (0.25in barb) (part# 2392695)
    9503-0014FGCuff/Hose Adapter (Clippard) for Adult Cuffs
    (part #2392642)
    •Critikon Dinamap
    • MDE
    •Invivo Research
    9503-0015FGCuff/Hose Adapter (Colder)(part# 2392656)
    •Protocol Systems
    9503-0018FGCuff/Hose Adapter (Luer locking male) (part# 2392688)
    9503-0016FGCuff/Hose Adapter (OBAC) (part# 2392663)
    •HP/Agilent/Philips
    •Alaris 4400
    9503-0020FGCuff/Hose Adapter (0.170 in barb) (part# 22392707)
    9503-0023FGCuff/Hose Adapter (0.25 in barb) (part# 2392718)
    •IVAC/Alaris 4200
    9503-0017FGCuff/Hose Adapter (Luer non-locking male) (part# 2392674)
    •Critikon
    •Dinamap
    •MDE
    •Invivo Research
    •SpaceLabs Medical for Neonatal Cuffs
    4920-0003FGQuick Disconnect Panel Mount Connector (replacement connector for NIBP interface) (part# 2392304)

    Batteries, Chargers, and Power Supply
    Battery - LI-MNO2BATTERY, Primary, LI-MNO2, 3V, 1.3AH
    (cylindrical, radial leads, 2/3A, 33x17mm)

    Cables
    3010-0016Cufflink Australia cordset (part# 2198760)
    AC power cable, detachable, 250V/10A
    3010-0462Detachable AC power cord (part #2200218)
    Denmark - 250v, 10A, AFSNIT 107-2-D1 to C13, 2.5m
    3010-0463Detachable Cord Set (part# 2200229)
    Old British/India/South Africa 250v,10A, SANS164-1 to C13
    3010-0465Detachable AC Cord Set (part# 2200241)
    Israel - 250v, 10A, SI1-16P to C13, 2.5m
    3010-0018Cufflink Italy Cordset (part# 2198785)
    AC power cable, detachable, 250V 10A

    Carrying Cases
    9530-0066Multi-purpose Hard-sided Watertight Carrying Case
    (part# 2248587)
    (contains pick-and-pluck foam) (19 " L x 14 " W x 7 ¾ " H)

    Miscellaneous Accessories
    5215-0268FGAdult Cuff Mandrel End Block (part# 2392370)
    (2 required)
    5215-0269FGAdult Cuff Mandrel Spacer Block (part# 2392381)
    (2 required)
    9513-0260CuffLink Adapter Kit (part# 2245300)
    (complete set of eight cuff/hose adapters)
    5027-0203FGNeonatal/External Cuff Mandrel, truncated plastic cylinder diameters: 7.6 cm, 10 cm, and 14 cm (part# 2392328) (for use with BP Pump 2/CuffLink)
    MANDREL-5001ProSim NIBP Mandrel Set (part# 4308086)

    Service Packages
    Care PlansRequest a quote
    Biomedical Equipment  |  Patient Simulator  |  Safety Analyzer  |  Dosimeter  |  Radiation Detector
    Related Products
    View related products
     
     CuffLink Adapter Kit »
     
     BP Pump 2 NIBP Blood Pressure Simulator »
     
     ProSim 8 Vital Signs Patient Monitor Simulator »
    ProSim 4 vital signs patient monitor simulation
    Follow us Fluke Biomedical on Facebook Fluke Biomedical on Twitter Fluke Biomedical on YouTube Fluke Biomedical on LinkedIn Home | Site Map | Fluke Corporation | Terms and Conditions | Privacy Statement | Disclaimer © 1995 - 2017 Fluke Corporation