BP Pump 2 NIBP Blood Pressure Simulator

 BP Pump 2 NIBP Blood Pressure Simulator
The BP Pump 2 provides dynamic blood-pressure simulations for testing adult and neonatal noninvasive BP monitors, including both arm- and wrist-cuff types. The analyzer features a preset mode for simulation of most patient conditions and the capability to program user-defined simulations. BP Pump 2 tests for leaks, measures static pressure, generates pressure, and tests overpressure valves. For improved testing versatility, the analyzer’s recently upgraded waveform test suite includes additional physiological selections. BP Pump 2 comes in two models: the standard BP Pump 2L and the BP Pump 2M, which features a high-accuracy pressure transducer. BP Pump 2 also includes an optional five-lead ECG test capability.
  • Dynamic simulations for arm- and wrist-cuff monitors
  • Physiological waveform
  • Internal pump for use in high- and low-pressure release verification, leak testing and pressure sourcing
  • Preset mode for simulation of most patient conditions
  • User-definable systolic and diastolic values, along with heart rate and pulse volume and user-defined autosequences
  • Internal cuff volume for basic device testing
  • Respiratory artifacts, including spontaneous breathing and controlled ventilation
  • Arrhythmia simulations, including premature atrial contractions #1 and #2, atrial fibrillation, and PVCs
  • PC based ansur test automation system to standardize testing protocol and documentation (optional)
  • High-accuracy pressure transducer (BP Pump2M only)
  • Dynamic pressure repeatability within 2 mmHg at maximal pulse size independent of device under test

Specifications
Display
Bright, large 4-line x 40 character alphanumeric display with backlighting
Pressure Generation/Measurement
Static-pressure range 50 mmHg to 400 mmHg(53 kPa)
Difference Between Target Pressure and Actual Pressure: -5 mmHg
Internal Leak Rate: < 2 mmHg per minute with minimum volume of 300 cc
Four Respiratory Artifacts
3 spontaneous breathing
controlled ventilation
3 Adult Wrist-Cuff Simulations
Normal
Hyper
Hypo
Pressure Source
Specified pressure generated from 50 mmHg to 400 mmHg in selectable increments of 1 mmHg
Pressure Gauge
Static pressure measured from 0 mmHg to 400 mmHg at the pressure port
Pressure Relief Rest
Test for the NIBPM pressure relief valve (0 mmHg to 400 mmHg) with display of peak pressure
Neonate Internal Cuff Simulations
Internal neonate cuff
Four standard neonate pressures
Normal Sinus Rhythm and Arrhythmias
BP and ECG - Healthy heart
- Weak pulse
- Mild exercise
- Strenuous exercise
- Obese subject
- Geriatric subject
- Tachycardia
- Bradycardia
Irregular Pulse
BP and ECG - Premature atrial contractions # 1
- Premature atrial contractions # 2
- Premature ventricular contractions
- Atrial fibrillation and PVCs
User-Definable Simulations
User-definable systolic and diastolic values, along with heart rate and pulse volume
Ranges:
Systolic Pressure Range: 20 to 250
Diastolic Pressure Range: 10 to 200
Dynamic NIBP Repeatability:
Within 2 mmHg (at maximal pulse size independent of device under test)
Heart Rate: 30 to 250
Pulse Volume: 0.1 cc to 2.4 cc
Performance Parameters
Max Pulse Volume: 2.4 cc
Max Heart Rate: - 200 BPM at 2.4 cc pulse volume
- 250 BPM at 1.2 cc pulse volume
Internal Neonatal Cuff Volume: 20 cc
Internal Adult Cuff Volume (Including NN Volume): 310 cc
Heart Rate Setting Accuracy: ± 1 BPM
Simulation Units: kPa and mmHg (user selectable)
Pressure Leak Test
The pressure port is pressurized from 0 mmHg to 400 mmHg and keeps track of the pressure loss over time. Peak pressure and present pressure are displayed at all times; leak rate is displayed when it is available.
Autosequences
Nine autosequences are provided for four tests and up to five simulations.
Electrical ECG
Signals: RA, LA, RL, LL, V
Waveform: Lead II
Amplitude: 1 mV peak (± 10 %)
Connections: Optional external ECG adapter
Physiological synchronization with non-invasive BP
Serial Port
Bidirectional RS232 port; baud rate of 9600 with no parity, one stop bit, and eight data bits.
Pressure Measurement
Pressure-Measurement Units: kPa, mmHg, cmH20, cmH2O and psi (user selectable)
Pressure-Measurement Range: 0 mmHg to 400 mmHg
Pressure-Measurement Resolution: 0.1 kPa, 1.0 mmHg, 1.0 cmH2O, and 0.1 psi
Pressure-Measurement Accuracy:
- Standard Version (BP Pump 2L): 0 to 300 mmHg: + 0.5 % of reading + 1 mmHg
301 to 400 mmHg: + 2 % of reading
- High-Accuracy Version (BP Pump 2M): ± 0.7 mmHg (0.09 kPa) throughout range
Parallel Port
25-pin female connector, with D-subminiature style and pinouts conforming to IBM "PC" printer port (unidirectional), HP and ASCII printers.
Sample Adult Arm-Cuff Simulation Parameters (Standard)
Standard Set of Blood Pressures
- BP #1 BP : 120/80 (93)
Heart Rate : 80
Pulse Volume : 0.68 cc
- BP #2 BP : 150/100 (116)
Heart Rate : 80
Pulse Volume : 0.65 cc
- BP #3 BP : 200/150 (166)
Heart Rate : 80
Pulse Volume : 0.60 cc
- BP #4 BP : 255/195 (215)
Heart Rate : 80
Pulse Volume : 0.55 cc
- BP #5 BP : 60/30 (40)
Heart Rate : 80
Pulse Volume : 0.75 cc
- BP #6 BP : 80/50 (60)
Heart Rate : 80
Pulse Volume : 0.70 cc
- BP #7 BP : 100/65 (76)
Heart Rate : 80
Pulse Volume : 0.69 cc
Dimensions
10 in L x 10 in D x 5 in H
(25.4 cm L x 25.4 cm D x 12.7 cm H)
Weight
7.5 lb
(3.4 kg)
Model NameDescription
BPPUMP2L-US120VBP Pump 2L Non-Invasive Blood Pressure Analyzer (standard pressure transducer)

All models include the following:
  • Accessory Kit (tubings and fittings) (2780003FG)
  • Operator's Manual
  • Power Cord (country specific)

BPPUMP2L-AUS250VBP Pump 2L, Australia, 250 V (standard pressure transducer)
BPPUMP2L-DEN250VBP Pump 2L, Denmark, 250 V (standard pressure transducer)
BPPUMP2L-SHK250VBP Pump 2L, Schuko, 250 V (standard pressure transducer)
BPPUMP2L-ISR250VBP Pump 2L, Israel, 250 V (standard pressure transducer)
BPPUMP2L-ITAL250VBP Pump 2L, Italy, 250 V (standard pressure transducer)
BPPUMP2L-IND250VBP Pump 2L, India 250 V (standard pressure transducer)
BPPUMP2L-SWZ250VBP Pump 2L, Switzerland, 250 V (standard pressure transducer)
BPPUMP2L-UK250VBP Pump 2L, United Kingdom, 250 V (standard pressure transducer)
BP Pump 2L, Brazil, 250 V (standard pressure transducer)BP Pump 2L, Brazil, 250 V (standard pressure transducer)
BPPUMP2M-US120VBP Pump 2M Non-Invasive Blood Pressure Analyzer (high-accuracy pressure transducer)

All models include the following:
  • Accessory Kit (tubings and fittings) (2780003F)
  • Operator's Manual (N/A)
  • Power Cord (country specific) (N/A)
BPPUMP2M-AUS250VBP Pump 2M, Australia, 250 V (high-accuracy pressure transducer)
BPPUMP2M-DEN250VBP Pump 2M, Denmark, 250 V (high-accuracy pressure transducer)
BPPUMP2M-SHK250VBP Pump 2M, Schuko, 250 V (high-accuracy pressure transducer)
BPPUMP2M-ISR250VBP Pump 2M, Israel, 250 V (high-accuracy pressure transducer)
BPPUMP2M-ITAL250VBP Pump 2M, Italy, 250 V (high-accuracy pressure transducer)
BPPUMP2M-IND250VBP Pump 2M, India, 250 V (high-accuracy pressure transducer)
BPPUMP2M-SWZ250VBP Pump 2M, Switzerland, 250 V (high-accuracy pressure transducer)
BPPUMP2M-UK250VBP Pump 2M, United Kingdom, 250 V (high-accuracy pressure transducer)
BPPUMP2M-BRAZ250VBP Pump 2M, Brazil, 250 V (high-accuracy pressure transducer)
TA-BPPMP2LBP Pump 2L, United States, 120 V (standard pressure transducer), with test automation
TA-BPPMP2L-AUSBP Pump 2L, Australia, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-DENBP Pump 2L, Denmark, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-SHK BP Pump 2L, Schuko, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-ISR BP Pump 2L, Israel, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-ITAL BP Pump 2L, Italy, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-IND BP Pump 2L, India, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-SWZ BP Pump 2L, Switzerland, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-UK BP Pump 2L, United Kingdom, 250 V (standard pressure transducer), with test automation
TA-BPPMP2L-BRAZBP Pump 2L, Brazil, 250 V (standard pressure transducer), with test automation
TA-BPPMP2M-US BP Pump 2M, United States, 120 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-AUS BP Pump 2M, Australia, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-DEN BP Pump 2M, Denmark, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-SHK BP Pump 2M, Schuko, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-ISR BP Pump 2M, Israel, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-ITAL BP Pump 2M, Italy, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-IND BP Pump 2M, India, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-SWZ BP Pump 2M, Switzerland, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-UK BP Pump 2M, United Kingdom, 250 V (high-accuracy pressure transducer), with test automation
TA-BPPMP2M-BRAZBP Pump 2M, Brazil, 250 V (high-accuracy pressure transducer), with test automation
BPPM2L/ECG-US BP Pump 2L, United States, 120 V, Testing Bundles (standard pressure transducer with 5 leads ECG Block)
BPPM2L/ECG-AUS BP Pump 2L, Australia, 250 V, Testing Bundles (standard pressure transducer with 5 leads ECG Block)
BPPM2L/ECG-ISR BP PUMP 2L, Israel, 250 V, Testing Bundles (standard pressure transducer with 5 leads ECG Block)
BPPM2L/ECG-ITAL BP PUMP 2L, Italy, 250 V, Testing Bundles (standard pressure transducer with 5 leads ECG Block)
BPPM2L/ECG-IND BP PUMP 2, India, 250 V, Testing Bundles (standard pressure transducer with 5 leads ECG Block)
BP PM2L/ECG-SWZ BP PUMP2L, Switzerland, 250, V Testing Bundles (standard pressure transducer with 5 leads ECG Block)
BPPM2L/ECG-UK BP PUMP 2L, United Kingdom, 250 V, Testing Bundles (standard pressure transducer with 5 leads ECG Block)

Cables
3370512 Dual 9DF serial cableSerial cable, D9F to D9F (part# 2204472)
71072Parallel printer cable, D25M to C36M (part# 2238072)
75034RS232 Interface cable (DB9M to DB9F) (part# 2238659)
for medTester to RF303RS (RS-232; male DB9 to female DB9; adapter required, 49755FG, part# 2391789)

Carrying Cases
5022010Soft vinyl carrying case (part# 2222822)

Miscellaneous Accessories
5215-0268FGAdult Cuff Mandrel End Block (part# 2392370)
(2 required)
5215-0269FGAdult Cuff Mandrel Spacer Block (part# 2392381)
(2 required)
2780512FG2780512FG, ECG Adapter Block (allows simulation of 5-lead ECG waveforms) (for use with BP Pump 2) (part# 2391894)
5027-0203FGNeonatal/External Cuff Mandrel, truncated plastic cylinder diameters: 7.6 cm, 10 cm, and 14 cm (part# 2392328) (for use with BP Pump 2/CuffLink)
98175FGWrist Cuff Mandrel, Adult (part# 2391875)

Printers
97116Printer paper DPU-414 and DPU-411 (part# 2248737)
(minimum 7 rolls – price is per roll)
PRINTR/414-US120VPrinter, SEIKO DPU-414-30B (part# 2248899)
Includes 120V PWR Supply (part# 2235375)
(Note: requires additional purchase of parallel printer cable, part# 2238072)
for use with ESA601/IDA 4 Plus/Index 2XL/QED 6/BP Pump 2
PRINTR414-SHK220VPrinter, Seiko DPU-414-30B with 220 V power supply (part# 2399531)
(NOTE: requires additional purchase of serial printer cable (part# 3370513)

Software
ANSUR BP PUMP 2Ansur BP Pump 2 Plug-In software (part# 2755836)

Service Packages
Care PlansRequest a quote
Biomedical Equipment  |  Patient Simulator  |  Safety Analyzer  |  Dosimeter  |  Radiation Detector
Search Fluke Biomedical
ResourcesProducts
Find Resources

    Follow us                      Home   |   Site Map   |   Fluke Corporation   |   Terms and Conditions   |   Privacy Statement   |   Disclaimer© 1995 - 2014 Fluke Corporation