 LT544Dplus Digital Safety Tester
This device is designed to perform simple electrical safety tests on any type of medical equipment, whenever patient lead testing is not required.

The rugged, hand-held instrument is built for quick and easy use. A simple selector knob controls the functions: Line Voltage, Instrument Current, Leakage Current and Chassis Resistance. Accurate test measurements are shown on the large display.

Heavy-duty switches change polarity, open and close the neutral and select Chassis or Earth Leakage Current measurements. A four-wire Kelvin bridge eliminates reading errors in resistance due to cable length and contact resistance. True RMS measurements are provided for all current readings. The AAMI test load is utilized.

  • Small, lightweight, self-contained portable instrument
  • Universal Power Supply. Input voltage from 85 - 265 VAC
  • Chassis Resistance measurements are made with a four-wire Kelvin bridge to eliminate errors due to cable length
  • Test method complies with AAMI load per ANSI/AAMI ES1-1993
  • Leakage Current can be measured in Open/Closed Neutral, Normal/Reversed Polarity and Open/Closed Ground.
  • All Leakage Current measurements are displayed directly in µAmps.

 

Specifications
Line Voltage
Range: 85 V ac to 265 V ac
Resolution: 1 Volt
Accuracy: 2 % Reading ± 1 LSD
Instrument Current
Range: 0 Amps to 19.99 Amps
Resolution: 10 mA
Accuracy: 5 % Reading ± 1 LSD
Ground Resistance
Range: 0 ohms to 19.99 ohms
Accuracy: ± 1 % Reading, ± 1 LSD
Resolution: 10 mOhms
Load Current
Range: 0 to 14.99A (LT544Dplus - 1515)
0 to 19.99A (LT544Dplus-2020)
0 to 9.99A (LT544Dplus-230V)
Accuracy: ± 4 % Reading, ±1 ISD
Leakage Current
Range: 0 µA to 1, 999 µA
Accuracy: DC&25 Hz to 1 kHz: ± 1 % Reading, ± 3 LSD
1 KHz to 100 KHz: ± 2.5 % of Reading, ± 3 LSD
100 KHz to 1 MHz: ± 5 % of Reading, ± 3 LSD
Current Capacity
LT544Dplus-1515: 15 Amps at 120 V ac
LT544Dplus-230V: 10 Amps at 230 V ac
LT544Dplus-2020: 20 Amps, at 120 V ac, 20 % duty cycle (2 minutes on, 8 minutes off)
Controls
1. Function Switch - 4 position rotary
2. Neutral Switch - 2 position rocker (Open/Closed)
3. Polarity Switch - 3 position rocker(Normal/Off/Reversed)
4. Leakage Switch - 2 position rocker (Chassis/Earth)
DUT Power
85 V ac to 265 V ac, 16 Amps @ 120 V, 10 Amps @ 230 V
Power Connectors
LT544Dplus ....................Standard US
LT544Dplus-EUR ..........Schuko
Physical Size
90 mm x 180 mm x 38 mm (3.5 in x 6.2 in x 1.6 in)
Model NameDescription
LT544Dplus-US Digital Safety Tester US, 85-265 V ac, 50/60 Hz (Item #2250854)

Includes:

  • Power Connector (country specific)
LT544Dplus-EUR Digital Safety Tester Europe, 85-265 V ac, 50/60 Hz (Item #2250893)

Includes:

  • Power Connector (country specific)
LT544Dplus-AUS Digital Safety Tester Austraila, 85-265 V ac, 50/60 Hz (Item #2250887)

Includes:

  • Power Connector (country specific)
LT544Dplus-ISR Digital Safety Tester Israel, 85-265 V ac, 50/60 Hz (Item #2250902)

Includes:

  • Power Connector (country specific)
LT544Dplus-ITL Digital Safety Tester Italian, 85-265 V ac, 50/60 Hz (Item #2250916)

Includes:

  • Power Connector (country specific)
LT544Dplus-SWS Digital Safety Tester Switzerland, 85-265 V ac, 50/60 Hz (Item #2250925)

Includes:

  • Power Connector (country specific)
LT544Dplus-UK Digital Safety Tester United Kingdom, 85-265 V ac, 50/60 Hz (Item #2250933)

Includes:

  • Power Connector (country specific)

Cables
600/100FGChassis Cable, coil cord, 8ft (part# 2392409)
(Standard test lead to be used with 175/180, a second lead can be used for dual lead resistance tests)
600/101FGChassis Cable, coil cord, 16 ft (part# 2392411)
(Could be used in place of standard test lead supplied with the 175/180, or as a second lead it can be used for dual lead resistance tests)
600/102FGChassis Ground Probe, 8ft coil (part# 2392427)
(this probe may be substituted for the 600/100 Chassis Cable, and used as a probe instead of a clamp)
600/215
600/215FG
Conductivity Cable (part# 2392533)
•ULT800 - for PCI GUS cleaning
•DALE 601/601E
•L544D lite/plus

Carrying Cases
600/600FGSoft Carrying Case (part# 2392584)
(6 in x 10 in x 4 in)

Service Packages
Care PlansRequest a quote
Biomedical Equipment  |  Patient Simulator  |  Safety Analyzer  |  Dosimeter  |  Radiation Detector
Search Fluke Biomedical
ResourcesProducts
Find Resources
Related Products
View related products
 
 ESA612 Electrical Safety Analyzer »
 
 ESA615 Electrical Safety Analyzer »
 
 ESA620 Electrical Safety Analyzer »

    Follow us                      Home   |   Site Map   |   Fluke Corporation   |   Terms and Conditions   |   Privacy Statement   |   Disclaimer© 1995 - 2014 Fluke Corporation